Input and output units

We offer a wide range of input and output units for many different applications. The system features Exn, Exia and Exd approved input and output units for high risk applications. All input and output units feature automatic addressing and short-circuit protection. All units can be used in all our interactive fire and gas detection systems unless otherwise stated.
Products:

Illustrasjonsbilde

AutroKeeper BN-180

For Dual Safety solution on AutroSafe systems.

Illustrasjonsbilde

Monitoring input unit BN-201

The unit is connected to the interactive detector loop, and is used for monitoring of fault or other signal contacts from external equipment.

Illustrasjonsbilde

Extinguishing control unit BN-221/01

Unit for monitoring and control of extinguishing equipment. IP67. For AutroSafe/AutroSafe IFG only.

Illustrasjonsbilde

Monitored output unit with 7A relay BN-221/02

Unit for activation of high current consuming equipment. Typical application: Horns and strobe lights. Maximum load current: 6A@24V, IP67. For AutroSafe only.

Illustrasjonsbilde

Input unit BN-300

Unit with one monitored input for connection of external alarm contacts etc. With SelfVerify.

Illustrasjonsbilde

Input unit BN-300M

Modular input unit with one monitored input, for connection of external alarm contacts etc. Mounting on DIN rail. With SelfVerify.

Illustrasjonsbilde

Single monitored input unit BN-303

For interfacing switches and 3rd party detectors with relay outputs to Autronica’s interactive fire detection systems. For Autroprime (1.1.0 or newer versions) and AutroSafe (4.3.1 or newer versions). With SelfVerify.

Illustrasjonsbilde

Single monitored input/output unit BN-304

For interfacing and controlling external units to Autronica’s interactive fire detection systems. For Autroprime (version 1.1.0 or newer) and AutroSafe (version 4.3.1 or newer). With SelfVerify.

Illustrasjonsbilde

Dual monitored input/output unit BN-305

For interfacing and controlling external units to Autronica’s interactive fire detection systems. With SelfVerify.

Illustrasjonsbilde

Dual monitored input/output unit BN-305-2

For interfacing and controlling external units to Autronica’s interactive fire detection systems, DIN-rail mounted. With SelfVerify.

Illustrasjonsbilde

Control and monitoring unit BN-305-D

For interfacing external units to our fire detection systems, DIN rail mounted.


Illustrasjonsbilde

Single relay output unit BN-310

Loop relay output unit with 1 potential free output. The unit is used for door release, sprinkler control/functions, and control of fire dampers. With SelfVerify.

Illustrasjonsbilde

Interface unit BN-320

Interface unit for detectors with special. Each unit with its own address. With SelfVerify.

Illustrasjonsbilde

Door control unit BN-320/2

Interactive door control unit, for control and monitoring of fire doors. With SelfVerify.

Illustrasjonsbilde

Monitoring and control unit BN-320/4

For monitoring and/or control of various external equipment, such as control of fire dampers, ventilation valves, fans, lifts, plus fire and smoke hatches. With SelfVerify.

Illustrasjonsbilde

Sprinkler control unit BN-320/5

For monitoring and control from sprinkler systems. With SelfVerify

Illustrasjonsbilde

Conventional loop interface module BNB-330A

Designed to monitor conventional fire detectors of the current increase type and to convey their status to the fire alarm control panel.

Illustrasjonsbilde

Conventional loop interface module BNB-331

2-wire interface unit for interfacing conventional detectors and manual call points onto Autronica’s interactive fire detection systems. DIN rail mounted.

Illustrasjonsbilde

Input unit BN-500/EX

With one monitored input, for connection of external alarm contacts etc. Approved for use in hazardous areas. With SelfVerify.

Illustrasjonsbilde

Input unit BN-500/N

With one monitored input, for connection of external alarm contacts etc. Approved for use in hazardous areas, zone 2. With SelfVerify.

Illustrasjonsbilde

Input unit BN-505/EXD

Input unit with BNB-300 and one monitored input. For use in hazardous area zone 1 or 2. With SelfVerify.